smartctl 6.3 2014-07-26 r3976 [x86_64-linux-4.4.2-hardened-cit-2] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital RE2-GP
Device Model: WDC WD1000FYPS-01ZKB0
Serial Number: WD-WCASJ0657732
LU WWN Device Id: 5 0014ee 2ab796fcb
Firmware Version: 02.01B01
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Mon May 2 08:40:23 2016 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (25560) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 293) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 200 199 051 Pre-fail Always - 17
3 Spin_Up_Time 0x0003 180 177 021 Pre-fail Always - 7966
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 97
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x000e 100 253 000 Old_age Always - 0
9 Power_On_Hours 0x0032 026 026 000 Old_age Always - 54234
10 Spin_Retry_Count 0x0012 100 253 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0012 100 253 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 97
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 332
193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 1643266
194 Temperature_Celsius 0x0022 122 094 000 Old_age Always - 30
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 4
198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 4
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
SMART Error Log Version: 1
ATA Error Count: 32 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 32 occurred at disk power-on lifetime: 54186 hours (2257 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ca 1a 40 40 Error: UNC at LBA = 0x00401aca = 4201162
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 00 80 1a 40 73 08 15d+02:47:11.908 READ FPDMA QUEUED
ef aa 00 00 00 00 00 08 15d+02:47:11.908 SET FEATURES [Enable read look-ahead]
ef 03 46 00 00 00 00 08 15d+02:47:11.908 SET FEATURES [Set transfer mode]
ef 02 00 00 00 00 00 08 15d+02:47:11.908 SET FEATURES [Enable write cache]
ef 03 0c 00 00 00 00 08 15d+02:47:11.908 SET FEATURES [Set transfer mode]
Error 31 occurred at disk power-on lifetime: 54186 hours (2257 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ca 1a 40 40 Error: UNC at LBA = 0x00401aca = 4201162
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 68 00 51 40 73 08 15d+02:47:06.731 READ FPDMA QUEUED
60 00 60 00 50 40 73 08 15d+02:47:06.731 READ FPDMA QUEUED
60 00 58 00 4f 40 73 08 15d+02:47:06.731 READ FPDMA QUEUED
60 38 50 90 e3 3b 3a 08 15d+02:47:06.731 READ FPDMA QUEUED
60 80 48 80 1e 40 73 08 15d+02:47:06.730 READ FPDMA QUEUED
Error 30 occurred at disk power-on lifetime: 54186 hours (2257 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 95 13 40 40 Error: UNC at LBA = 0x00401395 = 4199317
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 00 80 13 40 73 08 15d+02:47:01.722 READ FPDMA QUEUED
ef aa 00 00 00 00 00 08 15d+02:47:01.722 SET FEATURES [Enable read look-ahead]
ef 03 46 00 00 00 00 08 15d+02:47:01.722 SET FEATURES [Set transfer mode]
ef 02 00 00 00 00 00 08 15d+02:47:01.722 SET FEATURES [Enable write cache]
ef 03 0c 00 00 00 00 08 15d+02:47:01.722 SET FEATURES [Set transfer mode]
Error 29 occurred at disk power-on lifetime: 54186 hours (2257 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 95 13 40 40 Error: UNC at LBA = 0x00401395 = 4199317
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 e8 00 51 40 73 08 15d+02:46:55.570 READ FPDMA QUEUED
60 00 e0 00 50 40 73 08 15d+02:46:55.570 READ FPDMA QUEUED
60 00 d8 00 4f 40 73 08 15d+02:46:55.570 READ FPDMA QUEUED
60 38 d0 90 e3 3b 3a 08 15d+02:46:55.570 READ FPDMA QUEUED
60 80 c8 80 1e 40 73 08 15d+02:46:55.570 READ FPDMA QUEUED
Error 28 occurred at disk power-on lifetime: 54186 hours (2257 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 e9 04 40 40 Error: UNC at LBA = 0x004004e9 = 4195561
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 00 80 04 40 73 08 15d+02:46:50.338 READ FPDMA QUEUED
ef aa 00 00 00 00 00 08 15d+02:46:50.338 SET FEATURES [Enable read look-ahead]
ef 03 46 00 00 00 00 08 15d+02:46:50.338 SET FEATURES [Set transfer mode]
ef 02 00 00 00 00 00 08 15d+02:46:50.338 SET FEATURES [Enable write cache]
ef 03 0c 00 00 00 00 08 15d+02:46:50.338 SET FEATURES [Set transfer mode]
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 52852 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.